Abstract:
To explore the feasibility of application of buried pipe fresh air system in solar greenhouse,three kinds of different air velocities (5.8,4.6,3.1 m?s-1) were set up and monitored the air temperature and humidity of inlet and outlet of system,and recorded the temperature in the five points in pipe,and then thermal characteristics of the system were calculated.The results showed that the daily temperature difference was 0.3 ℃.Under conditions of 5.8,4.6,3.1 m?s-1,the new air temperature increased 7.8-8.9,9.8-11.9,6.3-7.8 ℃,and air humidity of outlet were 42.3%-52.0%,35.4%-40.3%,61.6%-83.6%,and enthalpy difference of outlet and inlet were 7.7-9.4,9.9-12.1,9.3-12.5 kJ?kg-1,and the absorbed heat by the soil were 23 160,23 492,14 884 kJ,respectively.Buried pipe fresh air system could significantly increased air temperature,and air humidity of the outlet was lower than indoor humidity,it had well capacity of absorption of heat.It illustrated that buried pipe fresh air system could be used to improve the air conditions in the solar greenhouse in winter.

References:

 

[1]李天来.我国日光温室产业发展现状与前景[J].沈阳农业大学学报,2005,36(2):131-138.

[2]李虎岗, 王双喜.节能日光温室研究现状与发展方向[J].现代农业科技,2015(13):241-243.

[3]王伟, 张京社, 王引斌.我国日光温室墙体结构及及性能研究进展[J].山西农业科学,2015,43(4):496-498.

[4]王克安,李絮花,吕晓惠,.不同结构日光温室温湿度变化规律及其对番茄产量和病害的影响[J].山东农业科学,2011(3):33-36.

[5]袁月明,王春野,刘海枝,.北方日光温室的冬季除湿技术[J].吉林农业大学学报,2016,38(1):122-126.

[6]TROMBE A,SERRRES L.Air-earth exchanger study in real site experimentation and simulation[J]Energy and Buildings,1994,21(2)155-162

[7]BOJIC M,TRIFUNOVIC N,PAPADAKIS GNumerical simulation,technical and economic evaluation of air-to-earth heat exchanger coupled to abuilding[J]Energy,1997,22(12):1151-1158

[8]WONTUG S,HIDEKI T.Study on fresh air load reduction system by air-to-earth heat exchanger using underground double floor space[J].Journal of Asian Architecture and Building Engineering,2001,2(1)41-48.

[9]桂玲玲, 张少凡. 地道风在建筑通风空调中的利用研究[J]. 广州大学学报(自然科学版),2010(5):67-72.

[10]吴俊涛,赵冰,湛文贤,.土壤空气换热建筑新风系统运行性能测试研究[J].河北工业大学学报,2014,43(1):81-87.

[11]刘宏,杜震宇,程远达.日光温室热湿环境作用下土壤-空气换热器动态换热特性的试验研究[J].科学技术与工程,2015,15(18):97-103.

[12]石发恩,高松涛,朱萌萌,.基于土壤能的地下埋管新风系统冷却能力研究[J].江西理工大学学报,2015,36(1):57-63.

[13]PFAFFEROTT J.Evaluation of earth-to-air heat exchangers with a standardised method to calculate energy efficiency[J].Energy & Buildings,2003,35(10):971-983.

[14]杨艳芳,刘雄,周敏.土壤空气换热系统在博物馆建筑中的应用研究[J].可再生能源,2014,32(9):1352-1358.

[15]王永维,苗香雯,崔绍荣,.温室地下蓄热系统换热特性研究[J].农业工程学报,2003,19(6):248-251.

[16]王永维,苗香雯,崔绍荣,.温室地下蓄热系统蓄热和加温性能[J].农业机械学报,2005,36(1):75-78.